AnalytikJena's exclusive High Performance UVB Transilluminator provide a total of 100-watts of high intensity UVB (302nm) ultraviolet illumination.The backlit UV illumination is further enhanced with AnalytikJena's UVG long-life filter and uniformity screen. The UV blocking cover is adjustable for access to the filter surface.
Features
The stainless steel frame enables easy cleaning,
The 3-step variable intensity settings allow the researcher to select high,
Medium or low intensity.
Specifications
Part Number
Volts
Model
Filter Size
95-0423-01
115V
TFM-20V
20x20cm
95-0423-02
240V
TFM-20V
20x20cm
95-0422-01
115V
TFM-26V
21x26cm
95-0422-02
240V
TFM-26V
21x26cm
95-0424-01
115V
TFM-30V
25x30cm
95-0424-02
240V
TFM-30V
25x30cm
95-0421-01
115V
TFM-40V
20x40cm
95-0421-02
240V
TFM-40V
20x40cm
Dimensions: 13.25D x 19.13W x 5.63H in. (337 x 486 x 143mm) Height includes UV blocking cover.
AnalytikJena's products are guaranteed to be free of defects in materials, workmanship and manufacture for one (1) year from date of purchase, except as follows:
- Consumable and disposable parts are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase.
- UV tubes and filters are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase.
- AnalytikJena Transilluminators are guaranteed to be free from defects in manufacture and materials for two (2) years from date of purchase.
If equipment failure or malfunction occurs during the warranty period, AnalytikJena shall examine the inoperative equipment and have the option of repairing or replacing any part(s) which, in the judgment of AnalytikJena , were originally defective or became so under conditions of normal usage and service.
No warranty shall apply to this instrument, or part thereof, that has been subject to accident, negligence, alteration, abuse or misuse by the end-user. Moreover, AnalytikJena makes no warranties whatsoever with respect to parts not supplied by AnalytikJena or that have been installed, used and/or serviced other than in strict compliance with instructions appearing in this manual.
In no event shall AnalytikJena be responsible to the end-user for any incidental or consequential damages, whether foreseeable or not, including but not limited to property damage, inability to use equipment, lost business, lost profits, or inconvenience arising out of or connected with the use of instruments produced by AnalytikJena . Nor is AnalytikJena liable or responsible for any personal injuries occurring as a result of the use, installation and/or servicing of equipment.
This warranty does not supersede any statutory rights that may be available in certain countries.