AnalytikJena SI-950 UV Sterilizing Incubator provides precise temperature control and uniformity throughout the chamber for incubation of biological assays, fungal, bacterial cultures, eggs and other biological samples. Designed to decontaminate the chamber between experiments with built-in shortwave UV.
Applications
Incubation,
Growth Experiments.
Features
Incubation applications are achieved using minimal benchtop space,
Microprocessor controlled temperature,
Heating element and fan generate uniform temperature throughout the chamber,
Overhead shortwave (254nm) ultraviolet sterilizes the chamber between experiments preventing cross contamination,
View samples without opening the door,
Two shelves included, adjustable at three positions,
Temperature: 68°C maximum.
Specifications
Shelves: Two ventilated shelves
Temperature: 68° C maximum
Accuracy: +/-1°C
Uniformity: +/-0.5°C at 37°C
Construction: Stainless steel interior
Dimensions:
Volume: 0.95 cubic feet (26.9 liters)
Exterior: 17.5W x 14.75D x 18H in. (445 x 375 x 457mm)
Shelf Area: 8.5D x 13.25W in. (216 x 337 mm)
Part Numbers
Volts
95-0358-01
115V
95-0358-02
230V
95-0358-03
100V
Warranty Information
AnalytikJena's products are guaranteed to be free of defects in materials, workmanship and manufacture for one (1) year from date of purchase, except as follows:
- Consumable and disposable parts are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase.
- UV tubes and filters are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase.
- AnalytikJena Transilluminators are guaranteed to be free from defects in manufacture and materials for two (2) years from date of purchase.
If equipment failure or malfunction occurs during the warranty period, AnalytikJena shall examine the inoperative equipment and have the option of repairing or replacing any part(s) which, in the judgment of AnalytikJena , were originally defective or became so under conditions of normal usage and service.
No warranty shall apply to this instrument, or part thereof, that has been subject to accident, negligence, alteration, abuse or misuse by the end-user. Moreover, AnalytikJena makes no warranties whatsoever with respect to parts not supplied by AnalytikJena or that have been installed, used and/or serviced other than in strict compliance with instructions appearing in this manual.
In no event shall AnalytikJena be responsible to the end-user for any incidental or consequential damages, whether foreseeable or not, including but not limited to property damage, inability to use equipment, lost business, lost profits, or inconvenience arising out of or connected with the use of instruments produced by AnalytikJena . Nor is AnalytikJena liable or responsible for any personal injuries occurring as a result of the use, installation and/or servicing of equipment.
This warranty does not supersede any statutory rights that may be available in certain countries.